Volume 13 Issue 3
Jun.  2020
Turn off MathJax
Article Contents
LUO Jing, ZHANG Xiao-hui, HE Xu, YE Lu, ZHANG Tian-yi. Effects of a misaligned photodetector in autocollimators on angle measurements[J]. Chinese Optics, 2020, 13(3): 558-567. doi: 10.3788/CO.2019-0207
Citation: LUO Jing, ZHANG Xiao-hui, HE Xu, YE Lu, ZHANG Tian-yi. Effects of a misaligned photodetector in autocollimators on angle measurements[J]. Chinese Optics, 2020, 13(3): 558-567. doi: 10.3788/CO.2019-0207

Effects of a misaligned photodetector in autocollimators on angle measurements

doi: 10.3788/CO.2019-0207
Funds:  Supported by National Natural Science Foundation of China (No. 61875190, No. 61675198)
More Information
  • Corresponding author: luojingopt@ciomp.ac.cn
  • Received Date: 24 Oct 2019
  • Rev Recd Date: 11 Nov 2019
  • Publish Date: 01 Jun 2020
  • As one of the key errors in autocollimators, misalignment of the photodetector is analyzed and modeled carefully in this paper. Effect of misalignment of the photodetector on angle measurements is characterized, when the photodetector in any position and orientation in space with respect to the theoretical image plane of autocollimators. It is shown that the angular measurement errors of autocollimators induced by a misaligned photodetector increase with greater measuring range L, larger angle θ and smaller focal length f of the collimating object lens. When f=300 mm, L=100 mm, θ=20″, the angular measurement error caused by a misaligned photodetector is 0.004 5″. The effects of each photodetector misalignment error on angle measurements in autocollimators are characterized. The model proposed in this paper is validated. Among all kinds of photodetector misalignment errors, the defocusing error has the greatest influences on autocollimators. Hence, it is critical to choose an imaging objective with longer focal length, reduce the measurement distance, and improve the installation accuracy of the photodetector along the axis. The model proposed in this paper helps to systematically obtain the angular measurement errors caused by a misaligned photodetector, which will play a key role in building a better error analysis model for autocollimators.

     

  • loading
  • [1]
    朱凡. 基于共光路光束漂移测量与同步补偿的激光自准直技术[D]. 哈尔滨: 哈尔滨工业大学, 2013.

    ZHU F. Laser autocollimation technology based on common-path beam drift measurement and synchronous compensation[D]. Harbin: Harbin Institute of Technology, 2013. (in Chinese)
    [2]
    黄银国. 激光自准直微小角度测量基础技术研究[D]. 天津: 天津大学, 2010.

    HUANG Y G. Study on micro-angle measuring basic technique of laser autocollimation[D]. Tianjin: Tianjin University, 2010. (in Chinese)
    [3]
    田留德, 赵建科, 王涛, 等. 测试设备位姿失调对自准直仪法测量圆分度误差的影响[J]. 光学 精密工程,2017,25(9):2267-2276. doi: 10.3788/OPE.20172509.2267

    TIAN L D, ZHAO J K, WANG T, et al. Influence of test equipment pose error on dividing error measurement based on autocollimator[J]. Optics and Precision Engineering, 2017, 25(9): 2267-2276. (in Chinese) doi: 10.3788/OPE.20172509.2267
    [4]
    杨飞, 安其昌, 张静, 等. 大口径光学系统的镜面视宁度检测[J]. 光学 精密工程,2017,25(10):2572-2579. doi: 10.3788/OPE.20172510.2572

    YANG F, AN Q CH, ZHANG J, et al. Seeing metrology of large aperture mirror of telescope[J]. Optics and Precision Engineering, 2017, 25(10): 2572-2579. (in Chinese) doi: 10.3788/OPE.20172510.2572
    [5]
    王国名, 劳达宝, 周维虎. 光电自准直经纬仪光学系统设计与公差分析[J]. 激光与光电子学进展,2017,54(10):102203.

    WANG G M, LAO D B, ZHOU W H. Optical system design and tolerance analysis of photoelectric self-collimation theodolite[J]. Laser &Optoelectronics Progress, 2017, 54(10): 102203. (in Chinese)
    [6]
    闫钰锋, 吴震, 王洋, 等. 温度变化对自准直仪机械结构的影响[J]. 光学仪器,2017,39(1):41-45.

    YAN Y F, WU ZH, WANG Y, et al. Effect of temperature on mechanical structure of autocollimator[J]. Optical Instruments, 2017, 39(1): 41-45. (in Chinese)
    [7]
    楼志斌, 赵辉, 刘权, 等. 结合激光准直的二维转角动态测量系统[J]. 光学 精密工程,2019,27(3):561-568. doi: 10.3788/OPE.20192703.0561

    LOU ZH B, ZHAO H, LIU Q, et al. Two-dimensional rotation angle dynamic measurement system combining laser collimation[J]. Optics and Precision Engineering, 2019, 27(3): 561-568. (in Chinese) doi: 10.3788/OPE.20192703.0561
    [8]
    何煦, 杨雪, 李颐, 等. 大口径空间光学望远镜重力卸载点布局优化方法[J]. 光学 精密工程,2018,26(11):2764-2775. doi: 10.3788/OPE.20182611.2764

    HE X, YANG X, LI Y, et al. Gravity compensation optimization algorithm for large aperture spatial optical telescope[J]. Optics and Precision Engineering, 2018, 26(11): 2764-2775. (in Chinese) doi: 10.3788/OPE.20182611.2764
    [9]
    JUST A, KRAUSE M, PROBST R, et al. Calibration of high-resolution electronic autocollimators against an angle comparator[J]. Metrologia, 2003, 40(5): 288-294. doi: 10.1088/0026-1394/40/5/011
    [10]
    GECKELER R D, JUST A. Optimized use and calibration of autocollimators in deflectometry[J]. Proceedings of SPIE, 2007, 6704: 670407. doi: 10.1117/12.732384
    [11]
    陈颖, 张学典, 逯兴莲, 等. 自准直仪的现状与发展趋势[J]. 光机电信息,2011,28(1):6-9. doi: 10.3788/OMEI20112801.0006

    CHEN Y, ZHANG X D, LU X L, et al. Current situation and development trend of autocollimator[J]. OME Information, 2011, 28(1): 6-9. (in Chinese) doi: 10.3788/OMEI20112801.0006
    [12]
    赵玉平, 彭川黔, 王劼. 大口径细光束自准直测量系统的误差源分析[J]. 半导体光电,2018,39(3):414-419.

    ZHAO Y P, PENG CH Q, WANG J. Analysis of error source for large aperture thin beam auto-collimating measurement system[J]. Semiconductor Optoelectronics, 2018, 39(3): 414-419. (in Chinese)
    [13]
    欧同庚, 陈志高, 杨博雄, 等. CCD光电自准直仪工作原理及误差源分析[J]. 大地测量与地球动力学,2007,27(S1):98-100.

    OU T G, CHEN ZH G, YANG B X, et al. Operating principle and error source of a new type of CCD photoelectric autocollimator[J]. Journal of Geodesy and Geodynamics, 2007, 27(S1): 98-100. (in Chinese)
    [14]
    张冬, 王振宏. PSD光电自准直仪工作原理及误差分析[J]. 机械工程师,2014(12):46-47. doi: 10.3969/j.issn.1002-2333.2014.12.019

    ZHANG D, WANG ZH H. Operation principle and error analysis of PSD photoelectric autocollimator[J]. Mechanical Engineer, 2014(12): 46-47. (in Chinese) doi: 10.3969/j.issn.1002-2333.2014.12.019
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(11)  / Tables(2)

    Article views(2469) PDF downloads(102) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return