Volume 11 Issue 5
Oct.  2018
Turn off MathJax
Article Contents
LIU Guo-dong, FANG Wei, SONG Bao-qi, YE Xin, WANG Kai. Diffraction effect correction of solar radiometer[J]. Chinese Optics, 2018, 11(5): 851-859. doi: 10.3788/CO.20181105.0851
Citation: LIU Guo-dong, FANG Wei, SONG Bao-qi, YE Xin, WANG Kai. Diffraction effect correction of solar radiometer[J]. Chinese Optics, 2018, 11(5): 851-859. doi: 10.3788/CO.20181105.0851

Diffraction effect correction of solar radiometer

doi: 10.3788/CO.20181105.0851
Funds:

National Natural Science Foundation of China 41474161

National High Technology Research and Development Program of China 2015AA123703

More Information
  • Corresponding author: FANG Wei, E-mail: fangw@ciomp.ac.cn
  • Received Date: 18 Dec 2017
  • Rev Recd Date: 21 Feb 2018
  • Publish Date: 01 Oct 2018
  • Solar radiation measurement is one of the important way to study solar activity and evolution of Earth's climate, which is of great significance to the sustainable development of human society. As one of the main sources of systematic errors in the measurement, diffraction effect must be accurately corrected so as to improve the reliability of the measurement data. China has little research on the diffraction effects in solar radiometers, and there are currently no related corrections. With the increase demand of the accuracy of solar radiation measurements, it is necessary to systematically study the diffraction effect. Firstly, the diffraction effect theory is studied. According to the Kirchhoff diffraction theory as well as the Gaussian optical approximation, the energy transfer relations between points and points, points and faces, and between faces is gradually determined, and the general formula of diffraction effect is derived. Then a simplified calculation method is obtained according to the asymptotic property of the diffraction effect. The diffraction effect of the Solar Irradiation Absolute Radiometer (SIAR) and the diffraction correction factor are then calculated through a simplified method. Finally, based on the diffraction correction results, the scaling factor relative to the World Radiation Reference (WRR) is calculated. As a result, the diffraction effects and diffraction correction factors of SIAR are about 1.002 742 and 0.997 225, respectively. In addition, the calibration coefficient of SIAR for WRR is closer to 1, indicating that the diffraction correction reduces the systematic error and improves the accuracy of the radiation measurement.

     

  • loading
  • [1]
    王玉鹏, 方伟, 弓成虎, 等.双锥腔互补偿型绝对辐射计[J].光学精密工程, 2007, 15(11):1662-1667. doi: 10.3321/j.issn:1004-924x.2007.11.005

    WANG Y P, FANG W, GONG CH H, et al.. Dual cavity inter-compensating absolute radiometer[J]. Opt. Precision Eng., 2007, 15(11):1662-1667.(in Chinese) doi: 10.3321/j.issn:1004-924x.2007.11.005
    [2]
    唐潇, 方伟, 骆杨, 等.低温绝对辐射计ARCPR热沉的热特性分析[J].光学学报, 2016, 36(10):1012004. http://cdmd.cnki.com.cn/Article/CDMD-80139-1017064021.htm

    TANG X, FANG W, LUO Y, et al.. Thermal analysis of an absolute cryogenic radiometer heat sink[J]. Acta Optica Sinica, 2016, 36(10):1012004.(in Chinese) http://cdmd.cnki.com.cn/Article/CDMD-80139-1017064021.htm
    [3]
    李同保.光辐射测量中的衍射修正问题[J].国外计量, 1979, 5:42-46. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=QK000003320094

    LI T B. Diffraction Correction in Optical Radiation Measurement[J]. Foreign Measurement, 1979, 5:42-46.(in Chinese) http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=QK000003320094
    [4]
    BORN M, WOLF E. Principles of Optics[M]. Oxford, UK:Pergamon Press Ltd., 1965.
    [5]
    WOLF E. Light distribution near focus in an error-free diffraction image[J]. Proc. Roy. Soc., 1951, A204:533-548. http://www.jstor.org/stable/98739
    [6]
    SHIRLEY E L. Revised formulas for diffraction effects with point and extended sources[J]. Appl. Opt., 1998, 37:6581-6590. doi: 10.1364/AO.37.006581
    [7]
    EDWARDS P, MCCALL M. Diffraction loss in radiometry[J]. Appl. Opt., 2003, 42:5024-5032. doi: 10.1364/AO.42.005024
    [8]
    SHIRLEY E L. Diffraction corrections in radiometry:Spectral and total power, and asymptotic properties[J]. J. Opt. Soc. Am., 2004, A21:1895-1906.
    [9]
    FOCKE J. Total illumination in an aberration-free diffraction image[J]. Optica Acta, 1956, 3:161-163. doi: 10.1080/713823678
    [10]
    OLVER F W J. Asymptotics and Special Functions[M].Wellesley, USA:A.K.Peters, Ltd., 1997.
    [11]
    方伟, 禹秉熙, 王玉鹏, 等.太阳辐照绝对辐射计及其在航天器上的太阳辐照度测量[J].中国光学, 2009, 2(1):23-28. doi: 10.3969/j.issn.2095-1531.2009.01.004

    FANG W, YU B X, WANG Y P, et al.. Solar irradiance absolute radiometers and solar irradiance measurement on spacecraft[J]. Chinese Journal of Optics, 2009, 2(1):23-28.(in Chinese) doi: 10.3969/j.issn.2095-1531.2009.01.004
    [12]
    BUTLER J J, JOHNSON B C, RICE J P, et al.. Sources of differences in on-orbital total solar irradiance measurements and description of a proposed laboratory intercomparison[J]. J. Res. Natl. Inst. Stand. Technol., 2008, 113:187-203. doi: 10.6028/jres
    [13]
    王玉鹏, 方伟, 禹秉熙.宽视场绝对辐射计的杂散光特性[J].光学精密工程, 2008, 16(3):432-436. http://d.old.wanfangdata.com.cn/Periodical/gxjmgc200803011

    WANG Y P, FANG W, YU B X. Stray light characteristics of WFOV absolute radiometer[J]. Opt. Precision Eng., 2008, 16(3):432-436.(in Chinese) http://d.old.wanfangdata.com.cn/Periodical/gxjmgc200803011
    [14]
    KOPP G, LEAN J L. A new, lower value of total solar irradiance:Evidence and climate significance[J]. Geophysical Research Letters, 2011, 38:L01706. doi: 10.1029-2010GL045777/
    [15]
    MARKUS S. Office of Scientific & Technical Information Technical Reports[R]. Advances in Solar Radiometry, 2014.
    [16]
    FINSTERLE W. International pyrheliometer comparison[R]. IPC-XⅡ, 2015.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(4)  / Tables(6)

    Article views(1648) PDF downloads(177) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return