  • A Microchannel Plate(MCP) photon detector was developed to detect the 30.4 nm radiation in a plasma layer of the earth. By changing voltages, temperatures and other parameters, the variations of the dark noise and resolution for the MCP detector were compared. The results indicate that the dark noise of the detector comes from the ion feedback of residual gas and the thermal noises mainly. Therefore, to reduce the dark noise, the microchannel should be preprocessed by removing residual gases and the detector could not work at a high temperature state. After preprocessing at the room temperature, the dark noise counting rate of the detector has reduced to 0.34 count/s穋m2. Furthermore, the temperature has a little effect on the resolution of the detector, and the resolution dependents on the variances of voltage or counting rate obviously. With different resist pressure abilities for different MCPs, it demonstrates that the proper voltage or counting rate can provide a better resolution.

     

  • loading
  • [1] SIEGMUND O H W. Advances in microchannel plate detectors for UV/visible astronomy[J]. SPIE,2003,4854:181-190. [2] 缪震华. 基于楔条形阳极探测器的单光子成像系统 .西安:中国科学院西安光学精密机械研究所,2008. MIAO ZH H. The single photon imaging system based on the wedge and strip anode detector . xian:xian Institute of Optics and Precision Mechanics of CAS,2008.(in Chinese) [3] 尼启良,刘世界,陈波. 极紫外位置灵敏阳极光子计数成像探测器研究[J]. 中国光学与应用光学 ,2009,2(1):36-40. NI Q L,LIU SH J,CHEN B. Investigation on extreme ultraviolet photon-counting imaging detector with position-sensitive anode[J]. Chinese J. Opt. Appl. Optics,2009,2(1):36-40.(in Chinese) [4] 何玲平,尼启良,李敏,等. 楔条形阳极光子计数探测器成像性能的检测[J]. 光学 精密工程 ,2009,17(11):2699-2704. HE L P,NI Q L,LI M,et al. Image performance of photon-counting imaging detector with wedge-and-strip anode[J]. Opt. Precision Eng.,2009,17(11):2699-2704.(in Chinese) [5] SIEGMUN O.H.W,VALLERGA J,WARGELIN B. Background events in microchannel plates[J]. IEEE T. Nucl. Sci.,1988,35(1):524-528. [6] 潘京生. 微通道板及其主要特征性能[J]. 应用光学 ,2004,25(5):25-29. PAN J SH. Microchannel plates and its main characteristics[J]. Appl. Optics,2004,25(5):25-29.(in Chinese) [7] SIEGMUND O H W. Preconditioning of microchannel plate stacks[J]. SPIE,1989,1072:111-118. [8] FRASER G W,PEARSON J F,LEES J E. Dark noise in microchannel plate X-ray detectors[J]. Nucl. Instrum. Methods,1987,254:447-462. [9] JOSEPH LADISLAS WIZA. Microchannel plate detectors[J]. Nucl. Instrum. Methods,1979,162:587-601. [10] 尼启良,何玲平,刘世界,等. 使用感应电荷位敏阳极的极紫外单光子计数成像系统[J]. 光学 精密工程 ,2010,18(12):2543-2548. NI Q L,HE L P,LIU SH J,et al.. Extreme ultraviolet single photon-counting imaging system based on induced charge position-sensitive anode[J]. Opt. Precision Eng.,2010,18(12):2543-2548.(in Chinese)
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(3225) PDF downloads(974) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return