Correction of chromatic aberration for human eyes with diffractive-refractive hybrid elements
-
摘要: 提出了采用两个折射-衍射元件对人眼系统在14范围内进行色差校正的光学系统设计方法。基于系统光学性能的评价与单片折射-衍射元件色差校正系统的对比验证了本文提出的色差校正系统的性能。结果表明:两种色差校正系统都可以很好地校正人眼的轴向色差。但是,单片折射-衍射色差校正系统引入了横向色差,其由校正前的14.51 m增加到81.4 m,严重影响了边缘视场处的成像质量。而采用双片折射-衍射元件的色差校正系统可同时对轴向色差和横向色差进行校正,使横向色差降为1.64 m。设计的色差校正系统可有效提高视网膜的成像质量,并可用于视觉仪器。Abstract: A chromatic corrector with two refractive-diffractive hybrid elements is designed for a wide field-of-view of 14 to correct chromatic aberrations in human eyes. The performance of the corrector based on several optical criteria is compared with a chromatic corrector with single refractive-diffractive element. Results show that both correctors can correct for Longitudinal Chromatic Aberration(LCA). However, it is demonstrated that the chromatic corrector with a single element introduces serious eccentric Transverse Chromatic Aberration (TCA) that increases from 14.61 m to 81.4 m. This deteriorates the image quality at the edge field-of-view. On the chromatic corrector with two refractive-diffractive elements, both the LCA and the TCA can be corrected and the TCA is just 1.64 m. The designed chromatic corrector can be used to improve the retinal image quality and has potential applications in the design of visual instruments.
-
[1] THIBOS L N,BRADLEY A,ZHANG X. The effect of ocular chromatic aberration on monocular visual performance[J]. Optom. Vis. Sci.,1991,68:599-607. [2] THIBOS L N,YE M,ZHANG X X,et al.. The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humans[J]. Appl. Opt.,1992,31(19):3594-3600. [3] MEETEREN A V,W C J,UNNEWOLD D. Image quality of the human eye for eccentric entrance pupils[J]. Vis. Res.,1983,23:573-579. [4] BEDFORD R E,WYSZECKI G. Axial chromatic aberration of the human eye[J]. J. Opt. Soc. Am.,1957,47:564-565. [5] THIBOS L N,BRADLEY A,STILL D L,et al.. Theory and measurement of ocular chromatic aberration[J]. Vis. Res.,1990,30:33-49. [6] RYNDERS M,LIDKEA B,CHISHOLM W,et al.. Statistical distribution of foveal transverse chromatic aberration, pupil centration, and angle psi in a population of young adult eyes[J]. J. Opt. Soc. Am. A,1995,12:2348-2357. [7] van HEEL A C S. Correcting the spherical and chromatic aberrations of the eye[J]. J. Opt. Soc. Am. A,1946,36(4):237-239. [8] LEWIS A L,KATZ M,OEHRLEIN C. A modified achromatizing lens[J]. Am. J. Optom. Physiol. Opt.,1982,59(11):909-911. [9] POWELL I. Lenses for correcting chromatic aberration of the eye[J]. Appl. Opt.,1981,20(24):4152-4155. [10] BENNY Y,MANZANERA S, PRIETO P M,et al.. Wide-angle chromatic aberration corrector for the human eye[J]. J. Opt. Soc.Am. A,2007,24(6):1538-1544. [11] DIAZ J A,IRLBAUER M,MARTINEZ J A. Diffractive-refractive hybrid doublet to achromatize the human eye[J]. J. Mod. Opt.,2004,51(14):2223-2234. [12] ISABEL E,NAVARRO R. Off-axis aberrations of a wide-angle schematic eye model[J]. J. Opt. Soc. Am.,1999,16(8):1881-1891.
点击查看大图
计量
- 文章访问数: 2297
- HTML全文浏览量: 212
- PDF下载量: 818
- 被引次数: 0