[1] SMARTT R N. Specialapplications of the point-diffraction interferometer[J]. SPIE, 1979, 192:35-40. https://www.researchgate.net/publication/234379228_titleSpecial_Applications_Of_The_Point-Diffraction_Interferometertitle
[2] SMARTT R N, STEEL W H. Point-diffraction interference microscopy[J]. Applied Optics, 1985, 24(10):1402-1403. doi: 10.1364/AO.24.001402
[3] SPEER R J, CHRISP M, TURNER D, et al.. Grazing-incidence interferometry-use of the linnik interferometer for testing image-forming reflection systems[J]. Applied Optics, 1979, 18(12):2003-2012. doi: 10.1364/AO.18.002003
[4] SMARTT R N. Point-diffraction interferometry as a diagnostic for alignment[J]. SPIE, 1984, 483:78-83.
[5] SMARTT R N, STEEL W H. Theory and application of point-diffraction interferometers[J]. Japanese Journal of Applied Physics, 1975, 14(S1):272-4. https://www.researchgate.net/publication/239048395_Theory_and_Application_of_Point-Diffraction_Interferometers
[6] GUO R, YAO B, GAO P, et al.. Parallel on-axis phase-shifting holographic phase microscopy based on reflective point-diffraction interferometer with long-term stability[J]. Applied Optics, 2013, 52(15):3484-3489. doi: 10.1364/AO.52.003484
[7] NOTARAS J, PATERSON C. Point-diffraction interferometer for atmospheric adaptive optics in strong scintillation[J]. Optics Communications, 2008, 281(3):360-367. doi: 10.1016/j.optcom.2007.09.045
[8] KIM Y, SHIM H, KIM K, et al.. Common-path diffraction optical tomography for investigation of three-dimensional structures and dynamics of biological cells[J]. Optics Express, 2014, 22(9):10398-10407. doi: 10.1364/OE.22.010398
[9] NEAL R M, WYANT J C. Polarization phase-shifting point-diffraction interferometer[J].Applied Optics, 2006, 45(15):3463-3476. doi: 10.1364/AO.45.003463
[10] MERCER C R, CREATH K. Liquid-crystal point-diffraction interferometer[J]. Optics Letters, 1994, 19(12):916-918. doi: 10.1364/OL.19.000916
[11] MEDECKI H, TEJNIL E, GOLDBERG K A, et al.. Phase-shifting point diffraction interferometer[J]. Optics Letters, 1996, 21(19):1526-1528. doi: 10.1364/OL.21.001526
[12] GONG Q, GEARY J M. Modeling point diffraction interferometers[J]. Optical Engineering, 1995, 35(2):351-356. https://www.researchgate.net/publication/253343057_Modeling_point_diffraction_interferometers
[13] STROJNIK M. Application of point-diffraction interferometry to testing infrared imaging systems[J]. SPIE, 2004, 5543:79-91. https://www.researchgate.net/publication/259663390_Application_of_point-diffraction_interferometry_to_testing_infrared_imaging_systems
[14] GONG Q. Alignment and testing of piston and aberrations of a segmented mirror[J].SPIE, 2005, 5869:586912. https://www.researchgate.net/publication/253842230_Alignment_and_testing_of_piston_and_aberrations_of_a_segmented_mirror
[15] MERCER C R, CREATH K. Liquid-crystal point-diffraction interferometer for wave-front measurements[J]. Applied Optics, 1996, 35(10):1633-1642. doi: 10.1364/AO.35.001633
[16] MERCER C R, RAMAN G. Quantitative interferometry in the severe acoustic environment of resonant supersonic jets[J]. AIAA Journal, 2012, 40(3):438-442. https://ntrs.nasa.gov/archive/nasa/casi.ntrs.nasa.gov/20000012457.pdf
[17] MERCER C R, CREATH K. Phase measurement using a liquid crystal point diffraction interferometer[J]. SPIE, 1995, 2349:95-99. https://www.researchgate.net/publication/24293441_Defocus_measurement_using_a_liquid_crystal_point_diffraction_interferometer
[18] GUARDALBEN M J, JAIN N. Phase-shift error as a result of molecular alignment distortions in a liquid-crystal point-diffraction interferometer[J]. Optics Letters, 2000, 25(16):1171-1173. doi: 10.1364/OL.25.001171
[19] MARSHALL K L. Recent advances in the development of phase-shifting liquid crystal interferometers for visible and near-IR applications[J]. SPIE, 2003, 5188(26):79-84. http://citeseerx.ist.psu.edu/viewdoc/download?doi=10.1.1.470.6799&rep=rep1&type=pdf
[20] MARSHALLK L, ADELSBERGER K, MYHRE G, et al.. The LCPDI:A compact and robust phase-shifting point-diffraction interferometer based on dye-doped LC technology[J]. Molecular Crystals & Liquid Crystals, 2006, 454(1):425-447. doi: 10.1080/15421400600654116
[21] KIHM H, LEE Y W. Double-pass point diffraction interferometer[J]. Measurement Science & Technology, 2010, 21(10):251-254. https://www.researchgate.net/publication/230908494_Double-pass_point_diffraction_interferometer
[22] IMADA H, MATSUO T, YAMAMOTO K, et al.. Real-time point-diffraction interferometer and its analytical formulation[J]. Applied Optics, 2015, 54(26):7870-7878. doi: 10.1364/AO.54.007870
[23] YAMAMOTO K, MATSUO T, IMADA H, et al.. Measurement of complex amplitude with a point-diffraction interferometer[J]. Applied Optics, 2015, 54(26):7895-7903. doi: 10.1364/AO.54.007895
[24] 刘克, 李艳秋.极紫外光刻投影物镜波像差在线检测技术[J].中国激光, 2009, 36(s2):257-262. http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201610036.htm

LIU K, LI Y Q. At-wavelength interferometry of projection optics for extreme ultraviolet lithography[J]. Chinese Journal of Lasers, 2009, 36(s2):257-262. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201610036.htm
[25] MERCER C R, CREATH K, RASHIDNIA N, Phase-stepped point diffraction interferometer using liquid crystals[J]. SPIE, 1995, 2544:87-93. http://proceedings.spiedigitallibrary.org/pdfaccess.ashx?url=/data/conferences/spiep/56818/87_1.pdf
[26] MERCER C R, RASHIDNIA N, CREATH K. High data density temperature measurement for quasi steady-state flows[J]. Experiments in Fluids, 1996, 21(1):11-16. doi: 10.1007/BF00204630
[27] MARSHALL K L, MYHRE G. A second-generation liquid crystal phase-shifting point-diffraction interferometer employing structured substrates[J]. SPIE, 2006, 5880:58800D. doi: 10.1117/12.617631
[28] PATURZO M. Phase-shifting point-diffraction interferometer developed by using the electro-optic effect in ferroelectric crystals[J]. Optics Letters, 2006, 31(24):3597-3599. doi: 10.1364/OL.31.003597
[29] PATURZO M, GRILLI S, FERRARO P. Point-diffraction interferometer by electro-optic effect in lithium niobate crystals[J]. SPIE, 2007, 6616:66160F. http://proceedings.spiedigitallibrary.org/pdfaccess.ashx?url=/data/conferences/spiep/17153/66160f_1.pdf
[30] AKONDI V, JEWEL A R, VOHNSEN B. Digital phase-shifting point diffraction interferometer[J]. Optics Letters, 2014, 39(6):1641-1644. doi: 10.1364/OL.39.001641
[31] NAULLEAU P P, GOLDBERG K A, LEE S H, et al.. Extreme-ultraviolet phase-shifting point-diffraction interferometer:A wave-front metrology tool with subangstrom reference-wave accuracy[J]. Applied Optics, 1999, 38(35):7252-7263. doi: 10.1364/AO.38.007252
[32] GOLDBERG K A, NAULLEAU P P, REKAWA S B, et al.. Ultra-high-accuracy optical testing:creating diffraction-limited short-wavelength optical systems[J]. SPIE, 2005, 5900:114-123. doi: 10.1117/12.618066
[33] SUGISAKI K, ZHU Y, GOMEI Y, et al.. Present status of the ASET at-wavelength phase-shifting point diffraction interferometer[J]. SPIE, 2000, 4146:47-53. https://www.researchgate.net/publication/252096576_Present_status_of_the_ASET_at-wavelength_phase-shifting_point_diffraction_interferometer
[34] 于长淞, 向阳.点衍射干涉仪小孔掩模技术研究进展[J].激光与光电子学进展, 2013, 50(3):030004. http://www.cnki.com.cn/Article/CJFDTOTAL-JGDJ201303005.htm

YU CH S, XIANG Y. Research progress of pinhole mask technology of point diffraction interferometer[J]. Laser and Optoelectronics Progress, 2013, 50(3):030004. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-JGDJ201303005.htm
[35] NEAL R M, WYANT J C. Polarization phase-shifting point-diffraction interferometer[J]. Applied Optics, 2006, 45(15):3463-3476. doi: 10.1364/AO.45.003463
[36] MILLERD J E, BROCK N J, HAYES J B, et al.. Instantaneous phase-shift, point-diffraction interferometer[J]. SPIE, 2004, 5531:264-272. https://www.researchgate.net/profile/Neal_Brock/publication/228538523_Instantaneous_phase-shift_point-diffraction_interferometer/links/0c960520289767aca7000000.pdf?disableCoverPage=true
[37] OUCHI C, KATO S, HASEGAWA M, et al.. EUV-wavefront metrology at EUVA[J]. SPIE, 2006, 6152:61522O. https://www.researchgate.net/publication/241368123_EUV-wavefront_metrology_at_EUVA
[38] ZHU Y, SUGISAKI K, OKADA M, et al.. Wavefront measurement interferometry at the operational wavelength of extreme-ultraviolet lithography[J]. Applied Optics, 2007, 46(27):6783-6792. doi: 10.1364/AO.46.006783
[39] WANG D, YANG Y, CHEN C, et al.. Misalignment aberrations calibration in testing of high-numerical-aperture spherical surfaces[J]. Applied Optics, 2011, 50(14):2024-2031. doi: 10.1364/AO.50.002024
[40] WANG D, YANG Y, CHEN C, et al.. Calibration of geometrical systematic error in high-precision spherical surface measurement[J]. Optics Communications, 2011, 284(16/17):3878-3885. https://www.researchgate.net/publication/229405147_Calibration_of_geometrical_systematic_error_in_high-precision_spherical_surface_measurement
[41] CHEN X, YANG Y, WANG C, et al.. Aberration calibration in high-NA spherical surfaces measurement on point diffraction interferometry[J]. Applied Optics, 2015, 54(13):3877-3885. doi: 10.1364/AO.54.003877
[42] 王道档, 杨甬英, 陈琛, 等.点衍射球面检测中的斜反射波前像差校正[J].光学学报, 2011, 31(6):0612003. http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201106020.htm

WANG D D, YANG Y Y, CHEN CH, et al.. Calibration of oblique reflection aberration in point-diffraction interferometer for high-precision spherical surface testing[J]. Acta Optica Sinica, 2011, 31(6):0612003. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201106020.htm
[43] 王道档, 杨甬英, 陈晓钰, 等.基于差分方法的高精度球面调整误差校正[J].光电子·激光, 2013(1):127-132. http://www.cnki.com.cn/Article/CJFDTOTAL-GDZJ201301024.htm

WANG D D, YANG Y Y, CHEN X Y, et al.. High-precision calibration of spherical surface misalignment based on difference method[J]. Journal of Optoelectronics·Laser, 2013(1):127-132. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GDZJ201301024.htm
[44] 张宇, 金春水, 马冬梅, 等.可见光移相点衍射干涉仪的空气扰动误差分析[J].红外与激光工程, 2012, 41(7):1899-1904. http://www.cnki.com.cn/Article/CJFDTOTAL-HWYJ201207039.htm

ZHANG Y, JIN CH SH, MA D M, et al.. Analysis of measuring errors for the visible light phase shifting point diffraction interferometer[J]. Infrared and Laser Engineering, 2012, 41(7):1899-1904. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-HWYJ201207039.htm
[45] GAO F, JIANG Z, ZHAO Z, et al.. Measurement of aspheric surface combining point diffraction interferometry and annular subaperture stitching[J]. Optical Engineering, 2015, 54(1):014102. doi: 10.1117/1.OE.54.1.014102
[46] GAO F, JIANG Z, LI B. Diffraction wavefront analysis of point diffraction interferometer for measurement of aspherical surface[J]. SPIE, 2010, 7656:276-279. https://www.researchgate.net/publication/252512851_Diffraction_wavefront_analysis_of_point_diffraction_interferometer_for_measurement_of_aspherical_surface
[47] 蒋庄德, 高芬, 李兵.点衍射干涉仪系统误差标定算法研究[J].机械工程学报, 2013, 49(16):48-56. http://www.cnki.com.cn/Article/CJFDTOTAL-JXXB201316009.htm

JIANG ZH D, GAO F, LI B. Research on system error calibration algorithm of point diffraction interferometer[J]. Journal of Mechanical Engineering, 2013, 49(16):48-56. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-JXXB201316009.htm
[48] 高芬, 蒋庄德, 李兵.不同对准误差下的小孔衍射波面误差分析[J].光学学报, 2014, 34(8):0812004. http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201408028.htm

GAO F, JIANG ZH D, LIB. Analysis of diffraction wavefront error caused by alignment error of pinhole[J]. Acta Optica Sinica, 2014, 34(8):0812004. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201408028.htm
[49] KIHM H, KIM S W. Fiber optic diffraction interferometer for testing spherical mirrors[J]. SPIE, 2002, 4777:394-400. https://www.researchgate.net/publication/238981749_Oblique_fiber_optic_diffraction_interferometer_for_testing_spherical_mirrors
[50] KIHM H, KIM S W. Oblique fiber optic diffraction interferometer for testing spherical mirrors[J]. Optical Engineering, 2005, 44(12):125601. doi: 10.1117/1.2148367
[51] KIHM H, KIM S W. Oblique point-diffraction source for interferometer design[J]. SPIE, 2003, 5144:240-249. doi: 10.1117/12.500253
[52] MATSUURA T, OKAGAKI S, NAKAMURA T, et al.. Measurement accuracy in phase-shifting point diffraction interferometer with two optical fibers[J]. Optical Review, 2007, 14(6):401-405. doi: 10.1007/s10043-007-0401-x
[53] MATSUURA T, UDAKA K, OSHIKANE Y, et al.. Spherical concave mirror measurement by phase-shifting point diffraction interferometer with two optical fibers[J]. Nuclear Instruments & Methods in Physics Research, 2010, 616(2/3):233-236. https://www.researchgate.net/publication/239356480_Spherical_concave_mirror_measurement_by_phase-shifting_point_diffraction_interferometer_with_two_optical_fibers
[54] CHKHALO N I, KLIMOV A Y, ROGOV V V, et al.. A source of a reference spherical wave based on a single mode optical fiber with a narrowed exit aperture[J]. Review of Scientific Instruments, 2008, 79(3):033107. doi: 10.1063/1.2900561
[55] CHKHALO N I, PESTOV A E, TOROPOV M N. Manufacturing and investigating objective lens for ultrahigh resolution lithography facilities[M]. Croatia:INTECH Open Access Publisher, 2010:71-114.
[56] SOMMARGREN G E. Phase shifting diffraction interferometry for measuring extreme ultraviolet optics[R]. Clifornia:Lawrence Livernore National Laboratory, 1996.
[57] SOMMARGREN G E, PHILLION D W, JOHNSON M A, et al.. 100-picometer interferometry for EUVL[J]. SPIE, 2002, 4688:316-328. https://www.researchgate.net/publication/253292454_100-picometer_interferometry_for_EUVL
[58] 古德温埃里克P, 怀亚特詹姆士C. 光学干涉检测[M]. 苏俊宏, 田爱玲, 译. 2版. 杭州: 浙江大学出版社, 2014.

GOODWIN E P, WYATT J C. Interferometric optical testing[M]. SU J H, TIAN A L, Transl. 2nd ed. Hangzhou:Zhejiang University Press, 2014. (in Chinese)
[59] LIANG N, MENGMENG H U, LIU B, et al.. Fiber point diffraction interferometer for measuring spherical surface[J]. SPIE, 2010, 7749:77490B.
[60] 张宇, 金春水, 马冬梅, 等.点衍射干涉仪波前参考源标定算法的研究[J].中国激光, 2012, 39(3):0308001. http://www.cnki.com.cn/Article/CJFDTOTAL-JJZZ201203032.htm

ZHANG Y, JIN CH SH, MA D M, et al.. Study of calibrating algorithm for wavefront reference source of point diffraction interferometer[J]. Chinese Journal of Lasers, 2012, 39(3):0308001. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-JJZZ201203032.htm
[61] TAKEUCHI S, KAKUCHI O, YAMAZOE K, et al.. Visible light point-diffraction interferometer for testing of EUVL optics[J]. SPIE, 2006, 6151:61510E. https://www.researchgate.net/publication/241367454_Visible_light_point-diffraction_interferometer_for_testing_of_EUVL_optics_-_art_no_61510E
[62] JOHNSON M A, PHILLION D W, SOMMARGREN G E, et al.. Construction and testing of wavefront reference sources for interferometry of ultra-precise imaging systems[J]. SPIE, 2005, 5869:58690P. https://www.researchgate.net/publication/252364351_Construction_and_testing_of_wavefront_reference_sources_for_interferometry_of_ultra-precise_imaging_systems
[63] 代晓珂, 金春水, 于杰.点衍射干涉仪波面参考源误差及公差分析[J].中国光学, 2014, 7(5):855-862. http://www.chineseoptics.net.cn/CN/abstract/abstract9183.shtml

DAI X K, JIN CH SH, YU J.Analysis on error and tolerance for the wavefront reference source of point diffraction interferometer[J]. Chinese Optics, 2014, 7(5):855-862. (in Chinese) http://www.chineseoptics.net.cn/CN/abstract/abstract9183.shtml
[64] 刘国淦, 张学军, 王权陡, 等.光纤点衍射干涉仪的技术研究[J].光学精密工程, 2001, 9(2):142-145. http://www.cnki.com.cn/Article/CJFDTOTAL-GXJM200102009.htm

LIU G G, ZHANG X J, WANG Q D, et al.. Fiber point diffraction interferometer[J]. Optics and Precision Engineering, 2001, 9(2):142-145. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXJM200102009.htm
[65] 曹晓君, 张学军, 李艳红.光纤点衍射干涉仪调整方法与条纹分析[J].光机电信息, 2003(3):28-30. http://www.cnki.com.cn/Article/CJFDTOTAL-GJDX200303009.htm

CAO X J, ZHANG X J, LI Y H. Adjustment method and fringe analysis of fiber point diffraction interferometer[J]. OME Information, 2003(3):28-30. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GJDX200303009.htm
[66] CHEN L F, NIE L, ZHOU T G, et al.. The comparison of two kinds of fiber phase shifting point-diffraction interferometer[J]. SPIE, 2007, 6279:627974. doi: 10.1117/12.725886
[67] WU S, ZHOU T G, LIN J M, et al.. Fiber point diffraction interferometer in measurement of spherical lens[J]. SPIE, 2007, 6624:662415. http://proceedings.spiedigitallibrary.org/pdfaccess.ashx?url=/data/conferences/spiep/17498/662415_1.pdf
[68] CHEN L F, REN Y Q, LI J.Flat surface measurements on fiber point diffraction interferometer[J]. Optical Engineering, 2010, 49(49):338-338. http://proceedings.spiedigitallibrary.org/pdfaccess.ashx?url=/data/journals/optice/22135/050503_1.pdf
[69] WU S, ZHOU T G, SHA D G, et al.. Key techniques in an absolute measurement method of spherical lens[J]. SPIE, 2008, 6834:683435. http://adsabs.harvard.edu/abs/2008SPIE.6834E..35W
[70] OTAKI K, BONNEAU F, ICHIHARA Y. Absolute measurement of spherical surface by point diffraction interferometer[J]. SPIE, 1999, 3740:602-605. https://www.researchgate.net/publication/252625449_Absolute_measurement_of_a_spherical_surface_using_a_point_diffraction_interferometer
[71] OTAKI K, OTA K, NISHIYAMA I, et al.. Development of the point diffraction interferometer for extreme ultraviolet lithography:Design, fabrication, and evaluation[J]. Journal of Vacuum Science & Technology B, 2002, 20(6):2449-2458.
[72] OTAKI K, YAMAMOTO T, FUKUDA Y, et al.. Accuracy evaluation of the point diffraction interferometer for extreme ultraviolet lithography aspheric mirror[J]. Journal of Vacuum Science & Technology B, 2002, 20(1):295-300. https://www.researchgate.net/publication/224467886_Accuracy_evaluation_of_the_point_diffraction_interferometer_for_extreme_ultraviolet_lithography_aspheric_mirror
[73] OTAKI K, ZHU Y, ISHⅡ M, et al.. Rigorous wavefront analysis of the visible-light point diffraction interferometer for EUVL[J]. SPIE, 2004, 5193:182-190. https://www.researchgate.net/publication/258717358_Analysis_of_pinhole_vector_diffraction_in_visible_light
[74] SEKINE Y, SUZUKI A, HASEGAWA M, et al.. Wave-front errors of reference spherical waves in high-numerical aperture point diffraction interferometers[J]. Journal of Vacuum Science & Technology B, 2004, 22(1):104-108. https://www.researchgate.net/publication/240668324_Wave-front_errors_of_reference_spherical_waves_in_high-numerical_aperture_point_diffraction_interferometers
[75] 马强, 刘伟奇, 李香波, 等.点衍射干涉仪中小孔衍射波面误差分析[J].光学学报, 2008, 28(12):2321-2324. doi: 10.3321/j.issn:0253-2239.2008.12.016

MA Q, LIU W Q, LI X B, et al.. Analysis of diffraction wavefront error in point diffraction interferometer[J]. Acta Optica Sinica, 2008, 28(12):2321-2324. (in Chinese) doi: 10.3321/j.issn:0253-2239.2008.12.016
[76] 卢增雄, 金春水, 张立超, 等.极紫外三维小孔矢量衍射波面质量分析[J].光学学报, 2010, 30(10):2849-2854. http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201010017.htm

LU Z X, JIN CH SH, ZHANG L CH, et al.. Wave-front quality analysis of three-dimension pinhole vector diffractional in extreme ultraviolet region[J]. Acta Optica Sinica, 2010, 30(10):2849-2854. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201010017.htm
[77] 卢增雄, 金春水, 马冬梅, 等.微小孔偏差对远场波前质量影响分析[J].光学学报, 2011, 31(8):0812002. http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201108022.htm

LU Z X, JIN CH SH, MA D M, et al.. Analysis of effect of tiny pinhole deviation on far-field wave-front quality[J]. Acta Optica Sinica, 2011, 31(8):0812002. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201108022.htm
[78] 卢增雄, 金春水, 马冬梅.照明物镜像差对远场衍射波前质量影响的严格矢量分析[J].光学学报, 2012, 32(8):0812001. http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201208016.htm

LU Z X, JIN CH SH, MA D M.Rigorous vector analysis of the effect of illumination objective lens aberration on the quality of far-field diffracted wave front[J]. Acta Optica Sinica, 2012, 32(8):0812001. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201208016.htm
[79] 王瑞林, 邢廷文, 谢伟民.可见光下三维针孔的衍射波面分析[J].激光技术, 2012, 36(3):382-385. http://www.cnki.com.cn/Article/CJFDTOTAL-JGJS201203026.htm

WANG R L, XING T W, XIE W M.Analysis of diffractive wave-front of 3-D pinhole under visible light[J]. Laser Technology, 2012, 36(3):382-385. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-JGJS201203026.htm
[80] 王瑞林, 张丽霞, 邢廷文.不同针孔直径下衍射波面的标量和矢量分析[J].光电技术应用, 2011, 26(6):58-61. http://www.cnki.com.cn/Article/CJFDTOTAL-GDYG201106014.htm

WANG R L, ZHANG L X, XING T W. Scalar and vector analysis of diffraction wave with different pinhole diameter[J]. Electro-Optic Technology Application, 2011, 26(6):58-61. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GDYG201106014.htm
[81] 许嘉俊, 邢廷文.可见光三维针孔形状误差矢量衍射分析[J].光电工程, 2013, 40(2):64-70. http://www.cnki.com.cn/Article/CJFDTOTAL-GDGC201302013.htm

XU J J, XING T W. Analysis of the wave-front diffracted by three-dimension pinhole with shape errors[J]. Opto-Electronic Engineering, 2013, 40(2):64-70. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GDGC201302013.htm
[82] 陈琛, 杨甬英, 王道档, 等.基于时域有限差分方法的点衍射波前误差分析[J].中国激光, 2011, 38(9):0908003. http://www.cnki.com.cn/Article/CJFDTOTAL-JJZZ201109033.htm

CHEN CH, YANG Y Y, WANG D D, et al.. Analysis of point-diffraction wavefront error based on finite difference time domain method[J]. Chinese Journal of Lasers, 2011, 38(9):0908003. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-JJZZ201109033.htm
[83] 邵卫红, 杨甬英, 陈晓钰, 等.点衍射干涉系统光学结构参数优化研究[J].强激光与粒子束, 2014, 26(5):10-16. http://cdmd.cnki.com.cn/Article/CDMD-10335-1014269230.htm

SHAO W H, YANG Y Y, CHEN X Y, et al.. Optimization research on optical structural parameters of point diffraction interference system[J]. High Power Laser and Particle Beams, 2014, 26(5):10-16. (in Chinese) http://cdmd.cnki.com.cn/Article/CDMD-10335-1014269230.htm
[84] 许嘉俊, 邢廷文, 徐富超.点衍射干涉仪系统误差标定[J].光学学报, 2013, 33(7):0712003. http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201307035.htm

XU J J, XING T W, XU F CH.Calibration of the system errors in pinhole diffracted interferometer[J]. Acta Optica Sinica, 2013, 33(7):0712003. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXXB201307035.htm
[85] 邵晶, 马冬梅, 聂真威.光学成像系统光学波前的高精度测试[J].光学精密工程, 2011, 19(11):2582-2588. http://www.cnki.com.cn/Article/CJFDTOTAL-GXJM201111004.htm

SHAO J, MA D M, NIE ZH W. Accurate test of optical wave front for optical imaging system[J]. Optics and Precision Engineering, 2011, 19(11):2582-2588. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-GXJM201111004.htm
[86] 王道档. 高精度点衍射球面干涉检测技术及系统研究[D]. 杭州: 浙江大学, 2012.

WANG D D. Point Diffraction Interferometricsystem for spherical surface testing[D]. Hangzhou:Zhejiang University, 2012. (in Chinese)
[87] WANG D, YANG Y, CHEN C, et al.. Point diffraction interferometer with adjustable fringe contrast for testing spherical surfaces[J]. Applied Optics, 2011, 50(16):2342-2348. doi: 10.1364/AO.50.002342
[88] WANG D, YANG Y, CHEN C, et al.. Polarization point-diffraction interferometer for high-precision testing of spherical surface[J]. SPIE, 2010, 7656:76560F.
[89] 卜敏, 雷海娜, 王亚伟.生物细胞形态检测光学技术的新进展[J].激光与光电子学进展, 2010, 47(7):071701. http://www.cnki.com.cn/Article/CJFDTOTAL-JGDJ201007008.htm

BU M, LEI H N, WANG Y W.New Progress on Detection of Biological Cells[J]. Laser and Optoelectronics Progress, 2010, 47(7):071701. (in Chinese) http://www.cnki.com.cn/Article/CJFDTOTAL-JGDJ201007008.htm
[90] POPESCU G, PARK Y, CHOI W, et al.. Imaging red blood cell dynamics by quantitative phase microscopy[J]. Blood Cells Molecules & Diseases, 2008, 41(1):10-16.
[91] KIM Y, SHIM H, KIM K, et al.. Common-path diffraction optical tomography for investigation of three-dimensional structures and dynamics of biological cells[J]. Optics Express, 2015, 23(15):18996. doi: 10.1364/OE.23.018996
[92] KIM Y, KIM K, KIM Y, et al.. Common-path diffraction optical tomography with a low-coherence illumination for reducing speckle noise[J]. SPIE, 2015, 9336:933629.