  • Publish Date: 01 Apr 2019
  • According to the optical beam superposition principle, a set of linearity measurement devices of spectrometer photoelectrical detecting system was developed. It consists of a 300 W super-quiet xenon lamp, a 250 W halogen tungsten lamp, a neutral filter group, double apertures and optical imaging system. The radiant power of the optical beams is manipulated with neutral filters and optical beam superposition is achieved using double apertures and optical imaging system. The spectral range of this device is 200-2 400 nm and the dynamic range of the linearity measurement is 104. It can simulate the extraterrestrial solar spectral irradiance and can be used for measuring linearity in solar spectrometer photoelectrical systems and silicon photodiode standard detection.

     

  • loading
  • [1]
    李志刚.基于探测器标准的高精度光谱辐射标准光源[J].中国光学, 2015, 8(6):909-918. http://www.chineseoptics.net.cn/CN/abstract/abstract9362.shtml

    LI ZH G. High accuracy spectroradiometric standard light source based on detector standard[J]. Chinese Optics, 2015, 8(6):909-918.(in Chinese) http://www.chineseoptics.net.cn/CN/abstract/abstract9362.shtml
    [2]
    LI ZH G, WANG X X, ZHENG Y Q, et al.. Absolute detector-based spectrally tunable radiant source using digital micromirror device and supercontinuum fiber laser[J]. Applied Optics, 2017, 56(17):5073-5079. doi: 10.1364/AO.56.005073
    [3]
    李福田, 李志刚, 王晓旭, 等.自校准型光谱辐亮度标准光源[J].光学 精密工程, 2017, 25(8):2004-2010. http://d.old.wanfangdata.com.cn/Periodical/gxjmgc201708005

    LI F T, LI ZH G, WANG X X, et al.. Self-calibrated spectral radiance standard source[J]. Opt. Precision Eng., 2017, 25(8):2004-2010.(in Chinese) http://d.old.wanfangdata.com.cn/Periodical/gxjmgc201708005
    [4]
    王淑荣, 李福田, 宋克非, 等.FY-3A气象卫星紫外臭氧垂直探测仪[J].光学学报, 2009, 29(9):2590-2593. http://d.old.wanfangdata.com.cn/Periodical/gxxb200909045

    WANG SH R, LI F T, SONG K F, et al.. Ultrariolet ozone vertical profile probe for FY-3A meteorological satellite[J]. Acta Optica Sinica, 2009, 29(9):2590-2593.(in Chinese) http://d.old.wanfangdata.com.cn/Periodical/gxxb200909045
    [5]
    O'DELL C W, DAY J O, POLLOCK R, et al.. Preflight radiometric calibration of the orbiting carbon observatory[J]. IEEE Transactions on Geoscience and Remote SensingI, 2010, 49(6):2438-2447.
    [6]
    LI ZH G, LIN CH, LI CH L, et al.. Prelaunch spectral calibration of a carbon dioxide spectrometer[J]. Measurement Science and Technology, 2017, 28(6):065801. doi: 10.1088/1361-6501/aa6507
    [7]
    THUILLIER G, FOUJOLS T, BOLSÉE D, et al.. SOLAR/SOLSPEC:scientific objectives, instrument performance and its absolute calibration using a blackbody as primary standard source[J]. Solar Physics, 2009, 257(1):185-213. doi: 10.1007/s11207-009-9361-6
    [8]
    SANDERS C L. Aphotocell linearity tester[J]. Applied Optics, 1962, 1(3):207-211. doi: 10.1364/AO.1.000207
    [9]
    SANDERS C L. Accurate measurements of and corrections for nonlinearities in radiometers[J]. Journal of Research of the National Bureau of Standards Section A:Physics and Cheimistry, 1972, 76(5):437-453.
    [10]
    BUDDE W. Multidecade linearity measurements on Si photodiodes[J]. Applied Optics, 1979, 18(10):1555-1558. doi: 10.1364/AO.18.001555
    [11]
    MIELENZ K D, ECKERLE K L. Spectrophotometer linearity testing using the double-aperture method[J]. Applied Optics, 1972, 11(10):2294-2303. doi: 10.1364/AO.11.002294
    [12]
    SAUNDERS R D, SHUMAKER J B. Automated radiometric linearity tester[J]. Applied Optics, 1984, 23(20):3504-3506. doi: 10.1364/AO.23.003504
    [13]
    THOMPSON A, CHEN H M. Beamcon Ⅲ, a linearity measurement instrument for optical detectors[J]. Journal of Research of the National Institute of Standards and Technology, 1994, 99(6):751-755. doi: 10.6028/jres.099.067
    [14]
    THEOCHAROUS E. Absolute linearity measurements on LiTaO3 pyroelectric detectors[J]. Applied Optics, 2008, 47(18):3397-3405. doi: 10.1364/AO.47.003397
    [15]
    THEOCHAROUS E. Absolute linearity measurements on a gold-black coated deuterated L-alanine-doped triglycine sulfate pyroelectric detector[J]. Applied Optics, 2008, 47(21):3731-3736. doi: 10.1364/AO.47.003731
    [16]
    THEOCHAROUS E. Reply to comments on "Absolute linearity measurements on a PbS detector in the infrared"[J]. Applied Optics, 2007, 46(25):6495-6497. doi: 10.1364/AO.46.006495
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(13)  / Tables(2)

    Article views(3114) PDF downloads(228) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return