Volume 5 Issue 4
Aug.  2012
Turn off MathJax
Article Contents
CHEN Jian, WANG Wei-guo, GAO Hui-bin, LIU Ting-xia, JI Tong-bo, YU Hong-jun. Radiation calibration for UV detectors and standard transferring[J]. Chinese Optics, 2012, 5(4): 423-429. doi: 10.3788/CO.20120504.0423
Citation: CHEN Jian, WANG Wei-guo, GAO Hui-bin, LIU Ting-xia, JI Tong-bo, YU Hong-jun. Radiation calibration for UV detectors and standard transferring[J]. Chinese Optics, 2012, 5(4): 423-429. doi: 10.3788/CO.20120504.0423

Radiation calibration for UV detectors and standard transferring

doi: 10.3788/CO.20120504.0423
  • Received Date: 11 Mar 2012
  • Rev Recd Date: 13 May 2012
  • Publish Date: 10 Aug 2012
  • To research the space optical remote sensing quantitatively and to improve the measuring accuracy of detectors in UV region, this paper analyzes the radiation calibration of the detectors and provides a standard transferring method. The working principle, establishing standard and the development status of UV detector standard-cryogenics radiometers are introduced in detail. Then, the selecting and the procedure of standard transmission of the transfer standard detector in Nation Institute of Standards and Technology(NIST) are discussed in-depth. The experimental results provide the theoretical foundation for the research on the detector calibration method and give the guidance for using the standard detector method to improve the calibration accuracy and accelerateing engineering application.

     

  • loading
  • [1] HEATH D F,KRUEGER A J,ROEDER H A,et al.. The solar backscatter ultraviolet and total ozone mapping spectrometer(SBUV/TOMS) for NIMBUSG[J]. Opt. Eng.,1975,14(4):323-331. [2] 刘建卓,王学进,黄剑波. 三波段电晕检测光学系统的设计[J]. 光学 精密工程 ,2011,19(6):1228-1234. LIU J ZH,WANG X J,HUANG J B. Design of three-band optical system used in corona detection[J]. Opt. Precision Eng.,2011,19(6):1228-1234.(in Chinese) [3] 黎海文,郝鹏,吴一辉. 微硅狭缝紫外-可见光谱仪杂散光的产生与抑制[J]. 光学 精密工程 ,2011,19(4):737-742. LI H W,HAO P,WU Y H. Generation and suppression of stray light in UV-vis spectrometer based on micro-silicon-slit[J]. Opt. Precision Eng.,2011,19(4):737-742.(in Chinese) [4] QUINN T J. Primary methods of measurement and primary standards[J]. Metrologia,1997,34(1):61-65. [5] LOSEV V,ALEKSEEV S,IVANOV N,et al.. Development of hybrid(solid/gas state) ultra-high power femtosecond laser system on the basis of XeF(C-A) amplifier[J]. Opt. Precision Eng., 2011,19(2):252-259. [6] TARASENKO V F,BAKSHTE K H,BURACHENKO A G,et al.. Formation of superpower volume discharges and their applications[J]. Opt. Precision Eng.,2011,19(2):273-283. [7] GENTILE T R,HOUSTON J M,HARDIS J E,et al.. National institute of standards and technology high-accuracy cryogenic radiometer[J]. Appl. Opt.,1996,35(7):1056-1068. [8] 张永生 郑国鑫. 500 fs紫外激光系统及其在闪烁体荧光特性测试中的应用[J]. 光学 精密工程 ,2011,19(2):475-481. ZHANG Y SH,ZHENG G X. 500 fs UV laser system and its application to fluorescence test of thin film scintillators[J]. Opt. Precision Eng.,2011,19(2):475-481.(in Chinese) [9] 赵阳,巩岩. 深紫外光刻照明系统光束整形单元的设计[J]. 光学 精密工程, 2011,19(1):29-34. ZHAO Y,GONG Y. Design of beam shaping unit for deep ultraviolet lithographic illumination system[J]. Opt. Precision Eng.,2011,19(1):29-34.(in Chinese) [10] STOCK K D,HOFER H. Present state of the PTB primary standard for radiant power based on cryogenic radiometry[J]. Metrologia,1993,30(4):291-296. [11] 吕亮. 低温辐射计计量特性、测量装置及量值传递方法的研究 .北京:中国计量科学研究院,2005. LV L. Study on cryogenic radiometer measurement characteristics, measuring devices and delivery method . Beijing:National Institute of Metrology,2005.(in Chinese) [12] 吴礼刚,何文荣,胡晋荪,等. 日盲紫外-可见光双光谱照相机系统[J]. 光学 精密工程 ,2010,18(7):1529-1535. WU L G,HE W R,HU J S,et al.. Solar blind UV and visible dual-spectral camera[J]. Opt. Precision Eng.,2010,18(7):1529-1535.(in Chinese) [13] 王淑荣,李福田,宋克非,等. 地外太阳紫外光谱测量[J]. 光学 精密工程 ,2010,18(6):1271-1277. WANG SH R,LI F T,SONG K F,et al.. Measurement of extraterrestrial solar ultraviolet spectrum[J]. Opt. Precision Eng.,2010,18(6):1271-1277 (in Chinese) [14] MARTIN J E,FOX N P,KEY P J. A cryogenic radiometer for absolute radiometric measurements[J]. Metrologia,1985,21(3):147-155. [15] 王玉恒,赵学庆,谭晓莉,等. 脉冲紫外激光和X射线辐照Al靶冲量耦合的异同性[J]. 光学 精密工程 ,2011,19(2):463-469. WANG Y H,ZHAO X Q,TAN X L. Similarity and distinction between impulse coupling with aluminum by pulsed ultraviolet laser and by X-ray[J]. Opt. Precision Eng.,2011,19(2):463-469.(in Chinese) [16] 何飞,陈波,张效信. 月基观测地球等离子体层极紫外辐射特性[J]. 光学 精密工程 ,2010,18(12):2564-2573. HE F,CHEN B,ZHANG X X. Moon-based imaging of earth plasmaspheric extreme ultraviolet radiation[J]. Opt. Precision Eng.,2010,18(12):2564-2573.(in Chinese) [17] KOHLER R,GOEBEL R,PELLP R. Experimental procedures for the comparison of cryogenic radiometer at highest accuracy[J]. Metrologia,1996,33(6):549-554. [18] DATLA R U,STOCK K. Characterization of an absolute cryogenic radiometer as a standard detector for radiant-power measurements[J]. Appl. Opt.,1992,1(34):7219-7225. [19] GOEBEL R,YILMAZ S,PELLO R. Polarization dependence of trap detector[J]. Metrologia,1996,33(3):455-460. [20] ZALEWSKI E F. The NBS Photodetector Spectral Response Calibration Transfer Program[M]. Gaithersburg, Maryland:US Dept. of Commerce, National Bureau of Standards, National Measurement Laboratory, Center for Radiation Research,1988. [21] SCHWINGER J. Electron radiation in high energy accelerators [J]. Phys. Rev.,1946, 70:798-798.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(3447) PDF downloads(1066) Cited by()
    Proportional views

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return